Reference Standards and Calibration

Every measurement made in the Velocity Interoperability Network is traceable, through an unbroken chain of comparisons, to the reference standards of measurement held in the custody of the Department. The Department maintains the standards, compares them with one another and with the standards of the laboratories, and calibrates the instruments of member organisations against them.

Traceability is what allows a measurement made by one organisation to be relied on by another. The Department calibrates instruments at its Calibration Laboratory at Northgate Relay; chemical analysers are calibrated at the Analytical Chemistry Laboratory against primary reference materials. A certificate of calibration issued by the Department records the standard applied, the results at each point and the uncertainty of the comparison.

Calibration service opens on Monday 7 September 2026

The calibration service begins with the opening of the Calibration Laboratory on 7 September 2026. Instruments may be submitted from that date; the schedule of services is published below.

The standards register. The register below records the reference standards in the Department's custody at establishment. Each standard is kept under controlled conditions by its custodian laboratory and is compared at least annually; artefacts are intercompared in pairs where two are held.

Reference standards of measurement in the Department's custody
QuantityStandard heldCustodian laboratoryUncertainty
Time and frequencyCaesium frequency standardNational Measurement Laboratory1 part in 10¹²
LengthIodine-stabilised laser interferometerNational Measurement Laboratory2 parts in 100 million
MassStainless-steel kilogram artefacts, Nos. 1 and 2National Measurement Laboratory0.05 milligrams
TemperatureTriple-point-of-water cellsCalibration Laboratory0.2 millikelvin
Electric potentialSolid-state voltage reference bankCalibration Laboratory0.5 parts in 10⁶
Mass fraction and purityPrimary reference materialsAnalytical Chemistry LaboratoryStated on each certificate

The Department keeps the register under review. A standard is replaced when its condition or uncertainty no longer serves the measurements made against it, and the replacement is announced in the Newsroom.

Calibration services. The services below are provided to member organisations and to the departments of the Network. The stated turnaround is the usual period from receipt of an instrument to the issue of its certificate, and applies at establishment; it will be reviewed in the light of demand.

Calibration services, from September 2026
Instrument groupLaboratoryUsual turnaroundSessions or intakes
Balances and scalesCalibration Laboratory5 working daysMonthly
Dimensional instruments (callipers, micrometers, gauges)Calibration Laboratory5 working daysMonthly
Thermometers and temperature probesCalibration Laboratory10 working daysMonthly
Electrical instruments (meters, oscilloscopes)Calibration Laboratory10 working daysMonthly
Pressure gauges and transducersCalibration Laboratory10 working daysFortnightly
Chemical analysersAnalytical Chemistry Laboratory15 working daysQuarterly

Submitting an instrument for calibration. The steps below apply to every calibration submitted to the Department.

  1. Step 1: Write to the Department

    Send a description of each instrument, its owner organisation and site, the accuracy required and the date by which it is needed, to the Department's email address. The Department confirms within two working days whether the work can be undertaken and when.

  2. Step 2: Send the instrument

    Send the instrument to the Calibration Laboratory at Northgate Relay, marked with the submission reference issued by the Department. Instruments should be sent in their protective cases where they have them.

  3. Step 3: The instrument is calibrated

    The instrument is compared against the reference standard for its quantity, across the range of its use. Where an instrument is adjusted, the readings before and after adjustment are both recorded.

  4. Step 4: The certificate is issued

    A certificate of calibration is issued bearing the instrument's identification, the standard applied, the results at each point and the uncertainty of the comparison. Instruments are returned to the sending organisation with the certificate.

Organisations holding instruments that fall outside these groups may write to the Department, which will advise whether the instrument can be calibrated or should be referred elsewhere. Enquiries about the standards register may be sent to contact@science.gov.vin. For the work of the six laboratories, see National Laboratories; for the committees that advise on the standards, see Scientific Advice; for answers to common questions, see the frequently asked questions.